Why do we use sample & injection quills?
Sample and injection quills are used in process systems for different, but related, purposes. Injection quills are used to introduce chemicals into a process stream, typically to treat the fluid or maintain the system. Sample quills, on the other hand, are used to extract fluid samples from the process stream for analysis.
Den Holder Sample and injection quills are specialized devices designed to safely introduce or extract fluids from a pressurized pipeline. Our design ensures chemical compatibility, mechanical integrity, and flow efficiency. Critical parameters such as wake frequency and unsupported length are considered to ensure
operational safety.
Specifications
Pressure
Upto 6000 psi (414 bar)
End connections
Flanged
Threded
Welded
Retractable (Hot Tapping)
Design codes
ASME B 31.3
ASME PTC 19.3TW
API RP14E
API 674/675
Insertion length
6”TO 48”(CUSTOM UPTO 72”)
Material
SS316 (L)
SS304,
HASTEALLOY C276
MONEL 400
INCONEL 625)
Tip type
OPEN END
DIFFUSER TIP
NON DRIP TIP
SPRAY TIP
ANGLED TIP

Our Sample and injection quills can be used in the oil and gas industry